Judges a rebuild against its reference copy and answers with one of three verdicts, naming every field that differed (crate#43):
Arguments
- a, b
Receipts, as lists from
crt_receipt_read(), or paths to them.ais the reference copy.- tables
Optional:
list(a = list(<table> = <data frame>), b = list(...)), the two builds' tables to re-read.- keys
Optional: the package's declaration, from
crt_receipt_keys(), whoseregisteroverrides the default action for fields outside the recipe.
Value
A list of class crt_receipt_comparison: verdict; mode, "receipts"
or "bytes"; and differences, a tibble with one row per field that differed:
side (output, recipe, result or context), field, action (refuse,
warn, record, or within for a difference inside its tolerance), and
detail; register, the version of the register the verdict was judged under;
and overrides, the action the declaration in keys gave each field whose action
it changed, named by field (empty when it changed none). It lists every such field,
whether or not that field differed in this comparison.
Details
identical: the same recipe and the same result.equivalent: the same recipe, and every result value that differs is within the tolerance the output declares.different: another recipe, or a result value past its tolerance.
What a difference in each field does comes from the receipt register
(inst/extdata/receipt/register/v1.0.0/register.csv, published at
https://newgraphenvironment.github.io/crate/receipt/register/v1.0.0/register.csv),
one row per field: refuse makes the
verdict different, warn is reported without changing it, and record is
listed only. Every recipe field refuses, because recipe_id covers it; every
context field is recorded, because the machine and the toolchain are never part
of an identity.
A verdict is a function of the register's rows, so the register is versioned on its own (crate#58) and every comparison names the version it was judged under. A row change is a new register version; it never moves the version a receipt carries, which is its form's.
Receipts or bytes
A comparison of receipts alone compares what the writers claimed. A table whose
fingerprints differ is then different, even when the difference is a value that
rounded the other way at the edge of its tolerance (0.0000000014 and 0.0000000016
under 1e-9). Supply both builds' tables and the comparison re-reads them: it checks
each against its own receipt's fingerprint, then compares their cells, and a table
whose cells all agree within tolerance is equivalent. The result's mode says
which was done.
A file whose bytes differ is equivalent only when its receipt names the table it
holds (parts, named, in crt_receipt_write()) and that table agrees; a file that
names no table, such as a raster nobody fingerprinted, is different.
Examples
wc <- system.file("extdata", "receipt", "examples", "worked_case", package = "crate")
crt_receipt_compare(file.path(wc, "build_1"), file.path(wc, "build_2"))
#> equivalent (receipts only; register v1.0.0)
#> within result.parts[access_check.csv].bytes: 124 vs 128; table access_check agrees
#> within result.parts[access_check.csv].sha256: "04994ff01cdee55d69fc410add51ad261ec4b33a751135fc224e97305823c3e2" vs "6801fb7bb092626441fd804d5ffbf8c4c05213ff18fa7c7ca524a9c2aa32f5e4"; table access_check agrees
#> within result.summary[km_total]: 47.3767792597 vs 47.376779259805; within 1e-06
#> record context.run: {"link_run_id":"20261104T181900Z-bulk"} vs {"link_run_id":"20261104T214400Z-bulk"}
#> record context.time: "2026-11-04T18:22:05Z" vs "2026-11-04T21:47:31Z"